Description
Product overview
Quote-only Mitutoyo Series 575 LGD ABSOLUTE linear gages with Digimatic output. Also useful for calibration labs, research QA programs, university labs, and traceable measurement workflows.
Mitutoyo Linear Gage LGD – Absolute, Standard Dimensions, Robust Series 575 is part of Mitutoyo Section G (Sensor Systems). Macroscopic Solutions supplies this product through a reviewed purchase or quote path so configuration, compatibility, shipping, freight, accessories, and support requirements can be confirmed before fulfillment.
Catalog reference: US-1005 G-12, G-13
Series 575 LGD ABSOLUTE linear gages maintain the reference point when power is switched off and provide Digimatic output.
Key specifications
| Order No. | Range | Resolution | Accuracy | Force up | Force horizontal | Force down | Mass | Stem dia. | Standard accessory |
|---|---|---|---|---|---|---|---|---|---|
| 575-326 | .4" / 10mm | .0005" / 10um | .001" / 20um | 1.0N or less | 1.1N or less | 1.2N or less | Approx. 260g | 8mm | Wrench for contact point No.538610 |
| 575-327 | 1" / 25mm | .0005" / 10um | .001" / 20um | 4.0N or less | 4.3N or less | 4.6N or less | Approx. 300g | 15mm | Wrench for contact point No.04GAA857 |
| 575-328 | 2" / 50mm | .0005" / 10um | 30um | 4.9N or less | 5.3N or less | 5.7N or less | Approx. 400g | 15mm | Wrench for contact point No.04GAA857 |
Shared specifications
| Specification | Value |
|---|---|
| Quantizing error | +/-1 count |
| Position detection method | ABSOLUTE electrostatic capacitance-type linear encoder |
| Response speed | Unlimited, not applicable to scanning measurement |
| Output | Digimatic output |
| External input | Reference-setting signal; absolute reference position can be changed externally |
| Contact point | 3mm carbide-tipped, fixing screw M2.5 (P=0.45×5), standard contact point No.901312 |
| Bearing type | Linear ball bearing |
| Dust/water resistance | Equivalent to IP66 (only gage head) |
| Output cable length | 2m, 3m, 5m, 7m directly extended from the main unit |
| Operating temperature / humidity | 0 to 40C (RH 20 to 80%, no condensation) |
| Storage temperature / humidity | -10 to 60C (RH 20 to 80%, no condensation) |
Accessories listed on catalog page G-12
| Order No. | Accessory |
|---|---|
| 02ADE230 | Air drive unit for 10mm range models |
| 02ADE250 | Air drive unit for 25mm range models |
| 02ADE270 | Air drive unit for 50mm range models |
| 238772 | Rubber boot for 10mm range models |
| 962504 | Rubber boot for 25mm range models |
| 962505 | Rubber boot for 50mm range models |
| 02ADB680 | Thrust stem set for 10mm range models |
| 02ADB681 | Thrust stem for 10mm range models |
| 02ADB682 | Clamp nut for 10mm range models |
| 02ADN370 | Thrust stem set for 25/50mm range models |
| 02ADN371 | Thrust stem for 25/50mm range models |
| 02ADB692 | Clamp nut for 25/50mm range models |
| 02ADB683 | Spanner wrench for 10mm range models |
| 02ADB693 | Spanner wrench for 25/50mm range models |
| 02ADF640 | SPC cable extension adapter |
| 02ADD950 | Extension cable 0.5m |
| 936937 | Extension cable 1m |
| 965014 | Extension cable 2m |
| 21EZA345A | Power supply and origin setter |
Applicable counters
| Order No. | Applicable counter |
|---|---|
| 542-007A | EC-101D Counter, 120V |
| 64PKA132 | EG-101D |
| 64PKA135 | EB-11D |
| 542-072A | EH-102D |
| 542-064 | EV-16D COUNTER |
Applications beyond production metrology
Common applications beyond production metrology include calibration support for research facilities, university measurement labs, engineering QA programs, instrument verification, standards rooms, and traceable measurement workflows for industrial R&D.
Application notes are general examples for discovery and planning; confirm suitability, tolerances, fixtures, standards, and regulatory requirements for the specific measurement task.












Reviews